Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

All Products

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Converters
  • Check Sources
  • Instrument Cases

Medical Physics

  • Radiation Safety QA
  • Imaging QA Test Tools
  • CT / MRI QA
  • Mammography QA
  • Ultrasound QA
  • Nuclear Medicine QA & Safety

Emergency Response Kits

  • General Response Kits
  • Medical Response Kits
  • Decontamination Kits

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Model 79/2
Model 79/2Model 79/2

Model 79/2

Stretch Scope Survey Meter

Part Number: 48-4203

Features

  • Lightweight - Approximately 1/3 the Weight of Comparable Instruments
  • 1.1 m (45 in.) to 4.5 m (177 in.) Telescoping Carbon Fiber Pole
  • Energy Compensated GM Detector
  • Range: 0.001 mSv/h to 0.04 Sv/h (0.1 mR/hr to 4 R/hr)
  • 1 µSv/h (0.1 mR/hr) Display Resolution
  • Backlit, Auto-Ranging LCD with Adjustable Viewing Angle
  • Simple Green, Yellow, and Red Status Indicators
  • 3-Button Intuitive Interface for Easy Operation
  • USB Port and All-Digital Calibration

The Model 79/2 Stretch Scope provides the operator with the ability to investigate areas of suspected gamma contamination while remaining at a greater distance from potentially high fields of radioactivity. The 4.5 m telescoping pole allows the attached detector to reach areas difficult to access with other types of instruments.

A large, easy-to-read LCD display rotates to maximize ease of viewing. Padded shoulder strap (included), audio warning tone, and easy, intuitive design are also featured. The unit’s body is made of durable, high-impact plastic with splash-resistant construction, allowing outdoor use.

The Model 79/1 has three modes of operation – RATE, MAX, and COUNT. Measurements can be collected in two sets of units (primary and secondary) for RATE and MAX modes in cps, cpm, Sv/h, mrem/hr, and R/hr units. The user can choose between two sets of units by simply pressing the Units button. An internal switch is used to enable or disable the front-panel setup feature to protect desired settings from inadvertent modification. Setup is also available via software from Ludlum Measurements (see the Options tab).

 

  • Specifications
  • Options
  • Documents
  • Firmware Updates
  • Video
  • Configurations
  • Specifications
  • Options
  • Documents
  • Firmware Updates
  • Video
  • Configurations

Specifications

Detector Internal energy-compensated GM
Detection Range 0.001 mSv/h to 0.04 Sv/h (0.1 mR/hr to 4 R/hr)
Energy Response Within 25% of true value from 60 keV to 3 MeV
Linearity ± 15% full range (dose rate)
LCD Display Auto-ranging, 3-digit LCD with large 13.4 mm (0.53 in.) digits, low-battery indicator, MAX, ALARM, MUTE
Units: (k)cps, (k)cpm, (k)Bq, (k)dpm, (μ)(m)R(/h), (μ)(m)Sv(/h), (μ)(m)rem(/h)
Display Range
  • 0.0 cps to 99.9 kcps
  • 0.00 cpm to 999 kcpm
  • 0.00 Bq to 99.9 kBq
  • 0.00 dpm to 999 kdpm
  • 0.00 μR/h to 999 R/h
  • 0.00 μSv/h to 999 Sv/h
  • 0.00 μrem/h to 999 rem/h
Display range can be set to limit display to calibrated range.
Backlight Built-in ambient light sensor automatically activates low-power LED backlight, unless internal dipswitch is set to continuous-on (will reduce battery life). Alarm light intensity varies based on ambient light levels.
User Controls
  • ON/OFF/ACK: Long press to turn ON; Tap to acknowledge alarms and silence alarm tone; Press to reset Sigma Audio alarm, turn "click" audio On/Off, turn Sigma Audio beep On/Off; Hold for OFF
  • Units: Long press changes the units between primary and secondary units
  • Mode: Long press alternates between NORMAL (count rate), MAX (captures peak rate), and COUNT (user-selectable preset count time from 0 to 10 min.). Number of modes can be reduced in setup.
Response Time User-selectable from 1 to 60 seconds, Auto-Response Rate FAST or SLOW, or Fixed FAST and SLOW
Alarms Alarm setpoints adjustable over the display range
Overload High count rate saturation protection to prevent the false display of lower count rates
Zero Protection After a user-settable number of seconds of no pulses from detector, the instrument will flash zero reading and the alarm audio will be triggered
Dead Time Correction Employs first and second order corrections for extended performance
Audio Greater than 75 dB at 0.6 (2 ft), approximately 4 kHz
Click Audio Divide x1, x10, x100, x1k
Power Two alkaline or two rechargeable “AAA” batteries (instrument does not support in-device charging)
Battery Life Approximately 100 hours of operation, 24-hour low battery warning
Construction Meter: High-impact plastic with separate battery compartment
Pole: Carbon fiber, telescoping
Temperature Range -20 to 50 °C (-5 to 122 °F)
May be certified for operation from -40 to 65 °C (-40 to 150 °F)
Environmental Rating NEMA rating of 4x or IP rating of 65
Size (H x W x L) 20.3 x 8.1 x 114 cm (8 x 3.2 x 45 in.) retracted, 4.5 m (177 in.) fully extended
Weight 1.4 kg (3 lb), including batteries and shoulder strap

Options

OptionDescriptionPart Number
Lumic Calibration Kit
Lumic Calibration Software allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. This software also includes a calibration wizard (guides the user through calibration steps) and a plateau wizard (determines the optimal detector operating voltage).

The kit includes Lumic Calibration Software versions 1.0 and 2.0, a Model 3000 Series USB cable, and a Model 30 family USB cable.
4519-865
Lumic Configuration Kit
Lumic Configuration Software allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. Does not include calibration or plateau wizards.

The kit includes the Lumic Configuration Software, a Model 3000 Series USB cable, and a Model 30 family USB cable.
4519-747
Headphone Jack
Adds headphone jack to instrument. 4498-697
m79_case_shut6
Model 79-Series Case
Rugged, dust- and waterproof transport and storage case. 2312979
Audio Hole Seal Option Reduces audio volume output. 4498-913
Decontamination Sleeve Protective plastic sleeve to cover pole and detector. 4272-630

Documents

  • Data Sheet
  • Product Manual

Firmware Updates

In order to use the latest Lumic Calibration Software*, you may need to update the firmware on your instrument. (All new instruments will be compatible with the latest software version.) Use the table below to determine the firmware requirement for your instrument.

Software Version Compatible Models Required Firmware
Lumic 1.0 30, 30-4, 30-6, 30-7, 35, 79 2.x or lower
3000, 3001, 3005, 3006, 3019, 3276 N34 or lower
3002, 3277 N12 or lower
Lumic 2.0 30, 30-4, 30-6, 30-7, 35, 79 3.x or higher
3000, 3001, 3005, 3006, 3019, 3276 N40 or higher
3002 N20 or higher
3003, 3014, 3078 N/A

*Note: If you purchased the original Lumic 1.0 software, you are eligible for a free copy of Lumic 2.0. Please contact your local sales representative or Ludlum Measurements to receive your copy.


To update the firmware on your instrument:
  1. Download the appropriate instructions file (PDF) for your instrument.
    IMPORTANT: The firmware update instructions are model number specific. You must use the instructions for your specific instrument model. See table below.

    Model Instructions File
    30, 30-4, 30-6, 30-7, 35, 79 Lumic Firmware Update Instructions (Model 30/35/79 Series)
    3000, 3001, 3002, 3005, 3006, 3019, 3276 Lumic Firmware Update Instructions (Model 3000 Series, Gen 1)
    3003, 3014, 3078 Lumic Firmware Update Instructions (Model 3000 Series, Gen 2)
  2. Download the latest Lumic Firmware Updater Software.
  3. Determine the printed circuit board number your instrument has. To do this, you must open the instrument can and find the number on the circuit board.
  4. Using the drop-down selectors below, select your instrument model and printed circuit board number. This will populate a list of available firmware downloads for your instrument.

Video

Models 30, 35, and 79 Device Menu Overview


Configurations

ModelDetectorRange
m79-w-strap
Model 79
Energy-Compensated GM Detector 10 µSv/h to 10 Sv/h
(1 mR/hr to 1000 R/hr)
m79slash2-w-strap
Model 79/1
CsI(Tl) Scintillator Detector 0.01 µSv/h to 500 µSv/h
(1 µR/hr to 50 mR/hr)
Model 79/2
Internal Energy-Compensated GM Detector 1 µSv/h to 10 mSv/h
(0.1 mR/hr to 1 R/hr)

Related Products

m79-w-strap
Model 79
m79slash2-w-strap
Model 79/1
m78-w-strap_500px
Model 78
m78_b3_2095008560
Model 78-1
m78-6_500px
Model 78-6
m78-9-w-strap_web
Model 78-9
Results 1 - 6 of 6

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.