Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

Health Physics

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Convertors
  • Check Sources
  • Instrument Cases

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m3078i-with-strap-angle_1357x700
m3078i-with-strap-angle_1357x700m3078-detectorm3078i-meter-closeup-w-screen_371x700m3078i-separatedm3078i-buttonsm3078i-in-use

Model 3078 Series

Stretch Scope

Features

  • Lightweight, Telescoping Carbon Fiber Pole - 1.3 to 4.7 m (4.1 to 15.3 ft.)
  • Range: 1 µSv/h to 10 Sv/h (0.1 mR/hr to 1000 R/hr)
  • 1 µSv/h (0.1 mR/hr) Display Resolution
  • Low, High, or Auto Range Selection
  • Rate, Max, Count, and Dose Modes
  • External Detector with 2 GM Tubes
  • Versions Available with Internal Detector for Dose Measurements
  • 4-Button Meter Interface for Easy Operation
  • 3-Button Handle Interface for Easy Feature Control
  • Digital Calibration and Data Logging
  • Large Backlit LCD for Ease of Reading
  • Lamp on End of Detector to Illuminate Inspection Area
  • Bluetooth and Headphone Options

The Model 3078 Series Stretch Scopes are designed to survey areas for gamma radiation while maintaining distance from potentially high radiation fields. These instruments include external GM detectors mounted at the end of a 4.7 m (15.3 ft.) carbon fiber telescoping pole, allowing the detector to reach areas difficult to access with other types of instruments. The Model 3078i versions have an additional internal GM or scintillation detector for monitoring user dose exposure.

The meter body is made of durable, high-impact plastic with splash-resistant construction for outdoor use. The instrument has a large, easy-to-read LCD with a backlight that adjusts to changing ambient light to provide optimum viewing in any conditions. User-adjustable audio levels provide the operator with audible clicks and alarms across all modes of operation. The meter is detachable so it can be used separately from the pole detector.

Each Model 3078 Series instrument has four modes of operation (RATE, MAX, COUNT, and DOSE) selectable using the MODE button. Measurements can be collected in two sets of units (primary and secondary) for all modes of operation by pressing the UNITS button. The external detector can operate in LOW, HIGH, or AUTO range modes by pressing the DET button. With data logging enabled, a simple press of the LOG button will record and time-stamp the current reading. Each instrument can store up to 1000 data points. On the Model 3078i versions, the internal detector runs continuously and reports accumulated dose measurements, which can be viewed at any time by pressing the PRG button.

 

  • Specifications
  • Configurations
  • Options
  • Documents
  • Firmware Updates
  • Video
  • Specifications
  • Configurations
  • Options
  • Documents
  • Firmware Updates
  • Video

Specifications

External Detector Two energy-compensated GM tubes
Internal Detector (3078i versions only) Energy-compensated GM or scintillation detector, see Configurations tab for options
Energy Response Within 25% of true value from 60 keV to 3 MeV
Linearity Readings within 10% of true value
Display Three-digit auto-ranging LCD. Units: (μ)(m)(k)(M)R(/h), (μ)(m)(k)(M)Sv(/h), (k)cps, (k)(M)cpm. Indicators: bar graph, mode (MAX, INTG), three alarm levels, fault messages (FAULT, OVERLOAD, LOSS OF COUNT, OVERRANGE), USB, wireless, audio, and low-battery.
Display Range 1 µSv/h to 10 Sv/h (0.1 mR/hr to 1000 R/hr)
Range Selection LOW range (1 µSv/h to 20 mSv/h, or 0.1 mR/hr to 2 R/hr);
HIGH range (8 mSv/h to 10 Sv/h, or 0.8 R/hr to 1000 R/hr);
or AUTO range across full display range
Display Backlight Built-in ambient light sensor automatically activates LED backlight unless internal dipswitch is set to continuous-on (will reduce battery life)
User Controls
  • ON/AUD: Extra-long press to turn ON; Short press to adjust audio level; Extra-long press to turn OFF
  • UNITS: Short press changes the units between count rate, dose/exposure, or disintegration
  • DETECTOR: Short press to switch active scope detector or enable auto-ranging; Extra-long press to switch between external and internal detector (3078i versions only)
  • LAMP/MODE: Short press alternates between modes: RATE (displays count rate), MAX (captures peak rate), COUNT (user-selectable preset count time from 0 to 31.68 years), and DOSE (current accumulated dose); Extra-long press enables/disables scope lamp
  • ACK/RST: Short press to acknowledge alarms; Extra-long press to reset current mode
  • LOG: Short press to log current display (requires Lumic Data Logger Kit, see Options) or initiate count in COUNT mode, extra-long press to change count in COUNT mode
  • PRG: Short press in first 4 seconds of power-up will grant access to setup menu
Response Time User-selectable from 1 to 60 seconds, auto SLOW, auto FAST, fixed SLOW (22 s), fixed FAST (4 s)
Alarms Three adjustable alarm setpoints for count rate, exposure/dose, count, and accumulated dose alarm set-points adjustable over the display range
Overload Protection High count rate saturation protection designed to prevent false display of lower count rates. If the instrument detects an overload condition, OVERLOAD will appear on the display and an audio warning will be triggered.
Loss of Count Protection After 60 seconds of no pulses from the detector, the instrument will flash a zero reading, an audio alarm will be triggered, and LOSS OF COUNTS will appear on the display
Overrange If the reading exceeds the predefined detector range, the instrument will flash a maximum reading, an audio warning will be triggered, and OVERRANGE will appear on the display
Audio Approximately 4 kHz, click audio greater than 65 dB at 0.6 m (2 ft.), alarm audio greater than 72 dB
Calibration Protection Internal dipswitch to disable front-panel calibration parameter changes
Power Four "AA" batteries
Battery Life Approximately 75 hours with no backlight (as low as 20 hours with backlight and lamp continuous-on), 16-hour low battery warning
Construction High-impact polycarbonate with rubber seals and separate battery compartment attached to telescoping carbon fiber pole
Temperature Range -20 to 50 °C (-5 to 122 °F)
May be certified for operation from -40 to 65 °C (-40 to 150 °F)
Environmental Rating NEMA rating of 3x
IP rating of 53
Size (H x W x L) 20.0 x 11.4 x 125.1 cm (7.9 x 4.5 x 49.25 in. [4.1 ft.]) retracted, fully extended length 466.7 cm (183.75 in. [15.3 ft.])
Weight 2.5 kg (5.4 lb) including batteries and shoulder strap

Configurations

ModelInternal Detector / RangePart Number
3078 NA 48-4332
3078i Energy-compensated GM
Background to 50 mSv/h (5 R/hr)
48-4337
3078i/1 CsI scintillator
Background to 500 µSv/h (50 mR/hr)
48-4337-1

Options

OptionDescriptionPart Number
Lumic Calibration Kit
Lumic Calibration Software allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. This software also includes a calibration wizard (guides the user through calibration steps) and a plateau wizard (determines the optimal detector operating voltage).

The kit includes Lumic Calibration Software versions 1.0 and 2.0, a Model 3000 Series USB cable, and a Model 30 family USB cable.
4519-865
Lumic Configuration Kit
Lumic Configuration Software allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. Does not include calibration or plateau wizards.

The kit includes the Lumic Configuration Software, a Model 3000 Series USB cable, and a Model 30 family USB cable.
4519-747
Lumic Data Logger Kit
(Model 3000-Series)
Includes Lumic Data Logger Software and cable. 4498-1019
worker_w_phone--instrument7
Model 3000 Series
Bluetooth® Option & Lumic Linker
Wirelessly connects the instrument with an Android or iOS mobile device. 4519-564
RS232 serial optionRS-232 Serial Port Adds a true RS-232 serial port connector. 4519-594
TTL serial optionTTL Serial Port Adds TTL 3.3 V serial port connector. Available modes are instrument dependent, contact us for more information on configuration options. 4519-595
Headphone Jack
Adds a headphone jack to the instrument. 4498-555
stereo_mono_headphones
Stereo/Mono Headphones
Adjustable stereo/mono headphones. 22-9313
m3000-series-shoulder-strap
Shoulder Strap
Replacement 1.8 m (6 ft) adjustable nylon shoulder strap. 22-9649
m4272-444_500px
Model 3078 Series Case
Rugged, watertight, crushproof, and dust proof transport and storage case. 4272-730

Documents

  • Data Sheet
  • Product Manual
  • CE Certificate
  • Model 3000 Series Comparison Table
  • Options for Model 3000 Series

Firmware Updates

In order to use the latest Lumic Calibration Software*, you may need to update the firmware on your instrument. (All new instruments will be compatible with the latest software version.) Use the table below to determine the firmware requirement for your instrument.

Software Version Compatible Models Required Firmware
Lumic 1.0 30, 30-4, 30-6, 30-7, 35, 79 2.x or lower
3000, 3001, 3005, 3006, 3019, 3276 N34 or lower
3002, 3277 N12 or lower
Lumic 2.0 30, 30-4, 30-6, 30-7, 35, 79 3.x or higher
3000, 3001, 3005, 3006, 3019, 3276 N40 or higher
3002 N20 or higher
3003, 3014, 3078 N/A

*Note: If you purchased the original Lumic 1.0 software, you are eligible for a free copy of Lumic 2.0. Please contact your local sales representative or Ludlum Measurements to receive your copy.


To update the firmware on your instrument:
  1. Download the appropriate instructions file (PDF) for your instrument.
    IMPORTANT: The firmware update instructions are model number specific. You must use the instructions for your specific instrument model. See table below.

    Model Instructions File
    30, 30-4, 30-6, 30-7, 35, 79 Lumic Firmware Update Instructions (Model 30/35/79 Series)
    3000, 3001, 3002, 3005, 3006, 3019, 3276 Lumic Firmware Update Instructions (Model 3000 Series, Gen 1)
    3003, 3014, 3078 Lumic Firmware Update Instructions (Model 3000 Series, Gen 2)
  2. Download the latest Lumic Firmware Updater Software.
  3. Determine the printed circuit board number your instrument has. To do this, you must open the instrument can and find the number on the circuit board.
  4. Using the drop-down selectors below, select your instrument model and printed circuit board number. This will populate a list of available firmware downloads for your instrument.

Video

Model 3078 Series

 

Model 3078 Series Webinar


Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.